Научная литература
booksshare.net -> Добавить материал -> Биология -> Тёрнер Э. -> "Биосенсоры: основы и приложения" -> 263

Биосенсоры: основы и приложения - Тёрнер Э.

Тёрнер Э., Карубе И., Уилсон Дж. Биосенсоры: основы и приложения — М.: Мир, 1992. — 614 c.
Скачать (прямая ссылка): biosensoriosnoviiprilojeniya1992.djvu
Предыдущая << 1 .. 257 258 259 260 261 262 < 263 > 264 265 266 267 268 269 .. 355 >> Следующая

Chem., 56, 263-8 (1984).
14. Fulton S. P.. Cooney C. L., Weaver J. C. Thermal enzyme probe
differential temperature measurements in a laminar flow-through cell.
Anal. Chem., 52, 505-8 (1980).
15. Grime J.K. Biochemical and clinical analysis by enthalpimetric
measurements - a realistic alternative approach? Anal. Chim. Acta, 118,
191-225 (1980).
16. Grime J. K. Application of solution calorimetry to biochemical and
clinical analyses. In Analytical solution calorimetry (ed. J.K. Grime),
p. 345. Wiley-Interscience, New York, 1985.
17. Grime J.K., Tan B. The determination of some selected penicillins by
enzymatic enthalpimetry. Anal. Chim. Acta, 107, 319-26 (1979).
18. Guilbault G.G., Danielsson B., Mandenius C.F., Mosbach K. A
comparison of enzyme electrode and thermistor probes for assay of
alcohols using alcohol oxidase. Anal. Chem., 55, 1582-5 (1983).
19. Johansson A., Mattiasson B., Mosbach K. Immobilized enzymes in
microcalorimetry. Methods in Enzymol, 44, 659-67 (1976).
20. Kiba N.. Tomiyasu Т., Furusawa M. Flow enthalpimetric determination
of glucose based on oxidation by 1,4-benzoquinone with use of immobilized
glucose oxidase column. Talanta, 31, 131-2 (1984).
21. Mandenius C.F., Billow L., Danielsson B., Mosbach K. Monitoring and
control of enzymic sucrose hydrolysis using on-line biosensors. Appl.
Microbiol. Biotechnol., 21, 135-42 (1985).
22. Marconi W. Biomedical applications of enzymatic fibres. In Enzyme
engineering (eds. G. B. Broun, G. Manecke, L. B. Wingard, Jr.), Vol. 4,
p. 179-86. Plenum Press, New York, 1978.
472
Глава 29
23. Martin С. J., Marini M. A. Microcalorimetry in biochemical analysis.
CRC Cirt. Rev. in Anal. Chem., 8, 221-86 (1977).
24. Mattiasson B., Danielsson B. Calorimetric analysis of sugars and
sugar derivatives with aid of an enzyme thermistor. Carbohydr. Res., 102,
273-82 (1982).
25. Mattiasson B., Mosbach K. A split-flow enzyme thermistor. Anal.
Lett., 9, 867-89 (1976).
26. Mattiasson B., Borrebaeck C., Sanfridsson B., Mosbach К. Thermometric
enzyme linked immunosorbent assay: TELISA. Biochim. Biophys. Acta, 483,
221-7 (1977).
27. Mattiasson B., Danielsson B., Winquist F., Nilsson H., Mosbach K.
Enzyme thermistor analysis of penicillin in standard solutions and in
fermentation broths. Appl. Environ. Microbiol., 41, 903-8
(1981).
28. Mattiasson B., Mandenius C.F., Axelsson J. P., Danielsson B.,
Hagander P. Computer control of fermentation with biosensors. Ann. N. Y.
Acad. Sci., 413, 193-6 (1983).
29. McGlothlin C.D., Jordan J. Enzymatic enthalpimetry, a new approach to
clinical analysis: glucose determination by hexokinase catalyzed
phosphorylation. Anal. Chem., 47, 786-90 (1975).
30. Mosbach K., Danielsson B. An enzyme thermistor. Biochim. Biophys.
Acta, 364, 140-5 (1974).
31. Mosbach K., Danielsson B. Thermal bioanalyzers in flow streams-enzyme
thermistor devices. Anal. Chem., 53, 83A-94A (1981).
32. Mosbach K., Borgerud A., Scott M. Determination of heat changes in
the proximity of immobilized enzymes with an enzyme thermistor and its
use for the assay of metabolites. Biochim. Biophys. Acta, 403, 256-65
(1975). .
33. Mosbach K., Mattiasson B., Gestrelius S., Srere P. A., Danielsson B.
Theoretical and practical aspects of immobilized multi-step enzyme
systems. In Enzyme engineering (eds. E. K. Pye, L. B. Wingard, Jr.), Vol.
2, p. 151. Plenum, New York, 1974.
34. Pennington S. N. A small volume microcalorimeter for analytical
determinations. Anal. Biochem., 72, 230-7 (1976).
35. Рое М., Gutfreund H., Estabrook R. W. Kinetic studies of temperature
changes and oxygen uptake in differential calorimeter: The heat of
oxidation of NADH and succinate. Arch. Biochem. Biophys., 122, 204-11
(1967).
36. Rehak N. N., Young D. S. Prospective applications of calorimetry in
the clinical laboratory. Clin. Chem., 24, 1414-19 (1978).
37. Rich S., laniello R. М., Jespersen N. D. Development and application
of a thermistor enzyme probe in the urea-urease system. Anal. Chem., 51,
204-6 (1979).
38. Satoh I., Danielsson B., Mosbach K. Triglyceride determination with
use of an enzyme thermistor. Anal. Chim. Acta, 131, 255-62 (1981).
39. Satoh I., Ogawa Т., Danielsson B. Calorimetric phospholipid
determination. Работа готовится к печати (1986).
40. Scheller F., Siegbahn N., Danielsson B.. Mosbach K. High-sensitivity
enzyme thermistor of L-lactate by substrate recycling. Anal. Chem., 57,
1740-3 (1985).
41. Schmidt H.-L., Krisam G., Grenner G. Microcalorimetric methods for
substrate determinations in flow streams with immobilized enzymes.
Biochim. Biophys. Acta, 429, 283-90 (1976).
42. Tran-Minh C., Vallin D. Enzyme-bound thermistor as an enthalpimetric
sensor. Anal. Chem., 50, 1874-8 (1978).
43. Weaver J.C., Cooney C. L., Fulton S. P., Schuler D" Tannenbaum S. R.
Experiments and calculation concerning a thermal enzyme probe. Biochim.
Biophys. Acta, 452, 285-91 (1976).
Предыдущая << 1 .. 257 258 259 260 261 262 < 263 > 264 265 266 267 268 269 .. 355 >> Следующая

Реклама

c1c0fc952cf0704ad12d6af2ad3bf47e03017fed

Есть, чем поделиться? Отправьте
материал
нам
Авторские права © 2009 BooksShare.
Все права защищены.
Rambler's Top100

c1c0fc952cf0704ad12d6af2ad3bf47e03017fed