Научная литература
booksshare.net -> Добавить материал -> Биология -> Тёрнер Э. -> "Биосенсоры: основы и приложения" -> 184

Биосенсоры: основы и приложения - Тёрнер Э.

Тёрнер Э., Карубе И., Уилсон Дж. Биосенсоры: основы и приложения — М.: Мир, 1992. — 614 c.
Скачать (прямая ссылка): biosensoriosnoviiprilojeniya1992.djvu
Предыдущая << 1 .. 178 179 180 181 182 183 < 184 > 185 186 187 188 189 190 .. 355 >> Следующая

access type glucose sensor for implantable artificial pancreas in vivo.
Trans. Am. Soc. Artif. Intern. Organs., 27, 250-3 (1981).
29. Kraegen E. W, Whiteside P.. Bell I) , Chia Y.O., Lazarus L.
Development of a closed-loop artificial pancreas. Horm. Metab. Res.
suppl., 8, 38-42 (1979).
30. Long heed W. D., Woulfe-Flanagan H., Clement I. R., Albisser A.M.
Insulin aggregation in artificial delivery systems. Diabetologia, 19, 1-9
(1980).
31. March W, Engerman R., Rabinovitch B. Optical monitor of glucose.
Trans. Am. Soc. Artif. Intern. Organs., 25, 28 31 (1979).
32. Mirouze J., Selam J. L, Pham Т. C" Cavadore D. Evaluation of
exogenous insulin homeostasis by the artificial pancreas in insulin
dependent diabetes. Diabetologia, 13, 273-8 (1977).
330
Глава 22
33. Nihon Н., Akerlind А. С., Mosbach К. Determination of glucose, urea
and penicillin using enzyme-pH electrodes, Biochim. Biophys. Acta, 320,
529-34 (1973).
34. Racine P., Mindt W. On the role of substrate diffusion in enzyme
electrodes. Experientia suppl., 18, 524-34 (1971).
35. Report of the National Commission on Diabetes to the Congress of the
United States. U.S. Dep. Health, Educ., Welfare, Public Health Service,
Nat. Inst, of Health, DHEW Publication No. (NIH) 76, 1021-8 (1976).
36. Richter G.J., Luft G., Gebhardt U. Development and present status of
an electrocatalytic glucose sensor. Diabetes Care, 5, 224-8 (1982).
37. Rizza R. A., GerichJ.E., Haymond M.W., Westland R. E., Hall L.D.,
Clemens A. H., Service F.J. Control of blood sugar in insulin dependent
diabetes: comparison of an artificial endocrine pancreas, continuous
subcutaneous insulin infusion, and intensified conventional insulin
therapy. N. Engl. J. Med., 303, 1313-8 (1980).
38. Scheller F" Janchen М., Pfeiffer D" Seyer I., Muller K.
Enzymelektrode zum Nachweis von Glucose. Z. Med. Labor. Diagn., 18, 312-
16 (1977).
39. Schiller J. G., Wingard L. B., Jr., Liu С. C. Potentiometric
detection of hydrogen peroxide and apparatus therefore. U.S. Patent, 4,
340, 448, 1982.
40. Schultz J. S., Mansouri S., Godlstein I. J. Affinity sensors: a new
technique for developing implantable sensors for glucose and other
metabolites. Diabetes Care, 5, 245-53 (1982).
41. Shichiri M" Yamasaki Y" Kawamori R., Hakui N., Abe H. Wearable
artificial endocrine pancreas with needle-type glucose sensor. Lancet, 2,
1129-31 (1982).
42. Shichiri М., Kawamori R., Hakui N., Yamasaki Y., Abe H. Closed-loop
glycaemic control with a wearable artificial endocrine pancreas.
Variation in daily insulin requirements to glycaemic responses'.
Diabetes, 33, 1200-2 (1984).
43. Slama G., Klein J.C., Tardieu M.C., Tchobroutsky G. Normalisation de
la glycemie par pancreas artificial miniaturise. Application pendant 24
heures chez 7 diabetiques insulino-dependants. Nouv. Presse Med., 6,
2309-15 (1977).
44. Soeldner J.S., Chang K.W., Aisenberg S., Hiebert J.M. Progress
towards an implantable glucose sensor and an artificial beta cell. In
Temporal aspects of therapeutics (eds. J. Urquhart, F. E. Yates), pp.
181-207. Plenum Press, New York-London, 1973.
45. Sorensen J. Т., Colton С. K" Hillman R. S., Soeldner J. S. Use of a
physiologic pharmacokinetic model of glucose homeostasis for assessment
of performance requirements for improved insulin therapies. Diabetes
Care, 5, 148-57 (1982).
46. Tchobroutsky G. Relation of diabetic control to development of
microvascular complications. Diabetologia, 15, 143-52 (1978).
47. Thevenot D. R. Problems in adapting a glucose oxidase electrochemical
sensor into an implantable glucose-sensing device. Diabetes Care, 5, 184-
9 (1982).
48. Thevenot D. R., Coulet P. R., Sternberg R., Gautheron D. C. A highly
sensitive glucose electrode using glucose oxidase collagen film.
Bioelectrochem. Bioenerg. 5, 548-53 (1978).
49. Updike S.J., Hicks G.P. The enzyme electrode. Nature, 214, 986-8
(1967).
50. Wightman R.M. Microvoltametric electrodes. Anal. Chem., 53, 1125-34A
(1981).
51. Wingard L.B., Jr. Possibility for an immobilised flavin fuel cell
electrode for glucose measurement. Diabetes Care, 5, 222-3 (1982).
52. Wingard L. B., Jr. Prospects for electrochemical devices and
processes based on biotechnology. In Biotech 83, pp. 613-24. Online
Publications Ltd., Northwood, UK, 1983.
53. Wingard L. B., Jr. Immobilized enzyme electrodes for glucose
determination for the artificial pancreas. Federation Proc., 42, 288-291
(1983).
54. Wingard L. B., Jr., Liu С. C., WolfsonS.K., YaoS.J., DrashA.L.
Potentiometric measurement of glucose concentration with an immobilized
glucose oxidase/catalase electrode. Diabetes Care, 5, 199-202 (1982).
55. Wingard L. B., Jr., Schiller J.G., Wolfson S. K., Liu С. C" Drash
A.L., Yao S.J. Immobilized enzyme electrodes for the potentiometric
measurement of glucose concentration: immobilization techniques and
materials. J. Biomed. Mater. Res., 13, 921-35 (1979).
Предыдущая << 1 .. 178 179 180 181 182 183 < 184 > 185 186 187 188 189 190 .. 355 >> Следующая